In a linear resonator, the transmission at a given wavelength is a single number. It does not change with the input intensity, and it makes no difference whether that intensity was reached from below or from above. Add a Kerr nonlinearity to the resonator and this no longer holds. Over a certain range, the same input intensity can give two different values of transmission. Why does the transmission depend on whether the intensity is being swept up or down?
This article answers that question and shows how to model optical bistability in a microring-type resonator with Lumerical FDTD. It follows the optical bistability example published by Ansys [1], in which the worked device is a plasmonic racetrack resonator, and it assumes you are comfortable reading a linear resonance spectrum. The aim is to help you decide whether the effect needs to be evaluated for your own resonator, whether you intend to study it, avoid it, or use it as a switch.
The worked example is a plasmonic racetrack resonator
The title says microring, and the mechanism described here is common to traveling-wave resonators coupled to a bus waveguide. The device in the Ansys example, however, is not a dielectric microring. It is a plasmonic racetrack resonator: a metal-dielectric-metal (MDM) plasmonic gap waveguide coupled to a racetrack cavity filled with a nonlinear Kerr medium, based on the design of Wang et al. [2]. The example runs as a 2D FDTD simulation, which the page notes can be run in either FDTD or the 2.5D FDTD propagator in MODE, and provides two project files, forward.fsp and reverse.fsp, and two scripts, set_source.lsf and bistability_results.lsf [1].
What the example demonstrates is the mechanism and the procedure. Its wavelengths, intensities and simulation times belong to this device and cannot be applied directly to a dielectric microring. The Ansys page does not list the dimensions or the material constants. They are defined in the project files, and this article does not restate them.
Step 1: Find the low-power transmission spectrum
Start with the linear response. In forward.fsp, disable the source “source_custom”, enable “source_broadband”, and change the material of the ring from “Kerr” to “Linear”. Run the simulation and plot the transmission from the monitor “T” [1]. This run contains no nonlinear material, so the spectrum shows where the resonances lie in the low-power limit. The example takes the resonance near 1550 nm as the reference for the nonlinear study.
Read two quantities from the spectrum: the resonance wavelength and the linewidth (the full width at half maximum of the dip). They are the basis for choosing the excitation wavelength in the next step.
Step 2: Detune the excitation wavelength from resonance and keep it fixed
With the Kerr effect, the refractive index depends on the optical intensity as n = n0 + n2I. For a positive nonlinearity, the index rises as more light is stored in the ring, the optical path lengthens, and the resonance moves to longer wavelengths.
The excitation is therefore placed on the long-wavelength side of the low-power resonance. The example uses a continuous wave at 1580 nm against a resonance near 1550 nm, and repeats the calculation at 1578 nm and 1582 nm [1]. At low intensity this wavelength is off resonance, and the transmission along the bus waveguide is higher than at the resonance wavelength.
The wavelength is held fixed throughout the sweep so that input intensity is the only variable under test. With the wavelength fixed, only the resonance moves, and what moves it is the light stored in the ring. The quantity of interest is how the transmission at one wavelength changes with intensity.
How far to detune is judged against the linewidth, not in nanometers. For a single resonance with an instantaneous Kerr response, coupled-mode theory gives a condition for bistability: the detuning (the difference between the excitation wavelength and the resonance wavelength) must exceed √3 times the half width at half maximum of the resonance, or about 0.87 times the full width [3]. With a smaller detuning, the transmission varies nonlinearly with intensity but remains single-valued. Beyond the condition, a range of intensity appears in which two states are possible. The Ansys results show the trend with detuning: as the excitation wavelength moves from 1578 nm to 1582 nm, the loop grows and shifts to higher intensity [1].
Why increasing and decreasing intensity follow different branches
Raise the input intensity from a low value. At first little light is stored in the ring and the resonance stays close to its low-power position. As the intensity increases, the stored light pulls the resonance slightly toward the excitation wavelength. More light can then enter, and the resonance moves a little further. Up to a point this feedback stays in balance and the state changes smoothly. At a certain input intensity the feedback runs away. The resonance moves onto the excitation wavelength, the energy in the ring jumps to a high value, and the transmission changes abruptly. This is the upper switching threshold.
Now lower the intensity from above that threshold. This time the ring starts with a large amount of stored light. The stored energy holds the resonance close to the excitation wavelength, and because the resonance is close, light keeps entering the ring. This self-sustaining state continues at input intensities where the increasing sweep was still off resonance. When the input falls further and reaches a second, lower threshold, the stored energy can no longer support the shift. The resonance returns to its original position, the light leaves the ring, and the transmission goes back to its earlier level. This is the lower switching threshold.
Between the two thresholds, two states satisfy the same equations for the same input intensity: one with almost no light in the ring and the resonance away from the excitation, and one with a large stored energy and the resonance on the excitation. A third solution lies between them, but it is unstable and the device does not remain there. Which stable state appears depends on the state the resonator was in before, and that is determined by the direction of the sweep. The transmission differs at the same input intensity because the energy already stored in the ring is different.
Step 3: Sweep the intensity up and down in Lumerical FDTD
Nonlinear material
The ring is filled with a material of the “Chi3/Chi2” type from the Material Database. This model adds a third-order susceptibility χ(3) term to the polarization of a base material, and χ(3) is entered in units of m2/V2 [4]. Ansys set χ(3) to ten times the value in the reference paper [2] so that bistability could be demonstrated at a lower intensity [1]. The intensity values in the example are therefore demonstration values, not those of the device in the paper.
Two properties of this material model affect accuracy. The automatic mesh is determined from the base material only, so if the nonlinear region needs a finer mesh, you add a mesh override region yourself. In addition, the simulation can become numerically unstable if the nonlinear perturbation is too large [4].
Source
The source is a continuous wave at a fixed wavelength whose intensity alone changes with time. In Lumerical this is a custom time signal, set with the script command setsourcesignal. A custom time signal is an advanced feature that is rarely needed outside nonlinear simulations [5]. In the example, the script set_source.lsf defines a signal whose intensity changes linearly between 0.01 and 0.5 (MW/cm2 on the horizontal axis of the result plots), and converts intensity to field amplitude using a waveguide index of 1.52 [1]. The ramp duration used in the example is 15,500 fs (15.5 ps).
The sweep here is not a set of steady-state calculations at separate intensities. It is two time-domain simulations: forward.fsp raises the intensity from the minimum to the maximum, and reverse.fsp lowers it from the maximum to the minimum over the same period [1]. Note that the auto shutoff does not act until a custom signal has ended [5].
Monitors and the plotted quantity
Time monitors at the input and output ports of the resonator record the field. The script bistability_results.lsf loads the results of the two simulations, removes the high-frequency components to obtain a clean output signal, and plots (Eout/Esource)2 against the source intensity [1].
Step 4: Compare the increasing and decreasing sweeps
The result to read is Figure 5(b) of the Ansys example, calculated at an excitation wavelength of 1580 nm. Its vertical axis is (Eout/Esource)2: the squared ratio of Eout, the field recorded by the time monitor at the output port, to Esource, the source field recorded at the input port. It is a dimensionless, normalized measure of transmission, not the transmitted power itself. The horizontal axis is the source intensity I (MW/cm2). The two curves correspond to increasing and decreasing source intensity.
Look for three things. At the low and high ends of the intensity axis, the two curves run close together. In between, they separate and enclose a loop. Within the loop, increasing intensity follows the upper branch and decreasing intensity follows the lower branch [1]. This follows from the port being observed. The example observes the through port of a waveguide with a side-coupled resonator, where the transmission is low when the resonator is on resonance. As the intensity increases, the resonator stays off resonance, on the high-transmission branch, up to the upper threshold. As the intensity decreases, it stays on resonance, on the low-transmission branch, down to the lower threshold. The intensities at which each curve leaves its branch are the two switching thresholds, and the interval between them is the bistable range.
Near the point where the decreasing-intensity curve returns to the upper branch, it rises briefly above that branch. The Ansys page does not discuss this feature. Before reading a threshold or a steady transmission level from a feature like this, run the checks in Step 5.
Step 5: Check the result with slower sweeps and fixed-intensity holds
In the example, the intensity changes continuously over the 15.5 ps ramp, so every point on the curves is recorded while the intensity is still changing. The Ansys page does not state whether the response has settled at each intensity. For your own model, two checks answer that question.
- Slow the sweep. Lengthen the ramp, extend the simulation time to match, and rerun both
forward.fsp and reverse.fsp. Compare the intensities at which the curves jump with those of the original run. If they move when the sweep is slowed, the result still depends on the sweep rate. Repeat until they stop moving.
- Hold the intensity. Use the same custom time signal mechanism to bring the source to a fixed intensity and keep it there, and follow (Eout/Esource)2 over time until it stops changing. Choose one intensity inside the loop and run it twice, once approaching from a lower intensity and once from a higher one. If the two runs settle at different values and stay there, the resonator is bistable at that intensity. If they settle at the same value, the difference seen in the sweep was not a stable state.
Treat the thresholds as results only after both checks.
From the result to a design decision
Researchers: identify the bistable range
Use the increasing and decreasing sweeps to find the bistable range: the interval of input intensity between the lower and the upper switching threshold at a given excitation wavelength. Repeating the sweeps at several wavelengths, as the Ansys example does at 1578 nm, 1580 nm and 1582 nm, shows how that range moves with detuning. You can also compare the smallest detuning at which a loop appears with the √3 condition [3] calculated from the linewidth of your own spectrum.
Filter designers: check whether the bistable range overlaps the operating range
For a filter, the point to check is whether the bistable range overlaps the range of intensity and wavelength in which the device is used. Run the increasing and decreasing sweeps up to the maximum operating intensity plus a margin, at the operating wavelength and at the edge of its tolerance on the side toward which the resonance shifts. If the two curves stay together over the whole operating range, the bistable range does not overlap it. Check separately how much the transmission changes with intensity in that range, because the Kerr shift changes the transmission even where there is no loop.
Optical switch designers: evaluate the two switching thresholds
For an optical switch or a memory element, the bistable range is the operating region. Evaluate the upper and lower switching thresholds, the interval between them, and the difference in transmission between the two branches at the intended holding intensity. Do this for your own geometry and materials. The thresholds in the Ansys example are specific to that device and its material settings.
Why you need to evaluate your own geometry and materials
There are three reasons why the numbers in the example do not apply to a different device.
- The example is a two-dimensional plasmonic structure. For a dielectric ring, you have to model your own structure: its coupling gap and bend loss, and the vertical confinement that a two-dimensional model does not contain.
- The Chi3/Chi2 material represents a χ(3) term only. In real devices other mechanisms can contribute. In silicon microrings, bistability has been demonstrated through a thermal nonlinearity [6]. A study of silicon-on-insulator ring resonators evaluated the carrier and thermal contributions and also observed pulsating behavior [7]. A model with only a χ(3) term does not include these.
- A larger ring means more computation and a longer simulation time. When the ring is too large to simulate in full, the linear spectrum that gives the resonance wavelength and the linewidth can be obtained with the methods described in Analyzing Large Ring Resonators: the Limits of a Full Solve and a Partitioned Approach.
Summary
The transmission can differ at the same input intensity because, in a resonator with a Kerr nonlinearity, the transmission is set by the energy stored in the ring, and that energy depends on the direction from which the intensity was reached. With the excitation wavelength fixed on the side toward which the resonance shifts, and with enough detuning, two stable states exist between a lower and an upper switching threshold. In the 1580 nm result of the Ansys example, increasing intensity follows the upper branch of (Eout/Esource)2 and decreasing intensity follows the lower branch.
In Lumerical FDTD the analysis runs in five steps: calculating the linear spectrum, fixing an excitation wavelength detuned from resonance, sweeping the intensity in each direction, comparing the two sweeps, and checking the result with slower sweeps and fixed-intensity holds. The thresholds support a design decision only for the geometry and materials that were simulated.
Last reviewed: 20 November 2026
References
- Ansys Optics, “Ring resonator – optical bistability”, https://optics.ansys.com/hc/en-us/articles/360041723954-Ring-resonator-optical-bistability
- X. Wang, H. Jiang, J. Chen, P. Wang, Y. Lu and H. Ming, “Optical bistability effect in plasmonic racetrack resonator with high extinction ratio,” Optics Express 19, 19415 (2011). https://doi.org/10.1364/OE.19.019415
- M. Soljacic, M. Ibanescu, S. G. Johnson, Y. Fink and J. D. Joannopoulos, “Optimal bistable switching in nonlinear photonic crystals,” Physical Review E 66, 055601(R) (2002). https://doi.org/10.1103/PhysRevE.66.055601
- Ansys Optics, “Advanced and custom optical material models in FDTD and MODE”, https://optics.ansys.com/hc/en-us/articles/360034394734-Advanced-and-custom-optical-material-models-in-FDTD-and-MODE
- Ansys Optics, “Creating a custom source time signal for an FDTD source”, https://optics.ansys.com/hc/en-us/articles/360034383114-Creating-a-custom-source-time-signal-for-an-FDTD-source
- V. R. Almeida and M. Lipson, “Optical bistability on a silicon chip,” Optics Letters 29, 2387-2389 (2004). https://doi.org/10.1364/OL.29.002387
- G. Priem, P. Dumon, W. Bogaerts, D. Van Thourhout, G. Morthier and R. Baets, “Optical bistability and pulsating behaviour in Silicon-On-Insulator ring resonator structures,” Optics Express 13, 9623-9628 (2005). https://doi.org/10.1364/OPEX.13.009623
Try the procedure on your own resonator
With an evaluation license, you can run the procedure in this article with your own geometry and material parameters.
Request a Lumerical FDTD evaluation