A metalens project appears to start with unit-cell simulation, but several decisions come first. What is the lens for? Under which conditions must it work, and how well? Which material and process will be used to make it?
This article is for engineers considering a first metalens project. It shows how to turn an application idea into a specification that can be used for design, software evaluation or a technical consultation. The fundamentals are covered in What Is a Metalens?, library building in Metalens Unit Cell Design, and a worked Lumerical and Zemax procedure in Metalens Design Across Lumerical and Zemax.
Start with the application and the system around the lens
The first decision is what the metalens must accomplish within the optical system. The function determines which items the specification is built around.
For focusing, the central items are wavelength, spot size and the power delivered to a defined region. For imaging, they are field of view, bandwidth, image size and contrast at each spatial frequency. Beam shaping is specified by the properties of the input beam, the target intensity profile and the tolerance for unwanted light. Coupling to a fiber or waveguide is specified by the mode size and numerical aperture on both sides, the misalignment tolerance and the coupling efficiency.
Next, write down what sits before and after the metalens: the type of source and the size of its emitting area, the divergence of the light that reaches the lens, the downstream element, which side of the substrate the light enters from, and the surrounding media (air, adhesive, cover glass).
Decide at this stage whether a single metalens does all the work, or whether it is combined with refractive lenses or an aperture stop. If that assumption changes, the required phase profile changes with it.
Optical requirements
Wavelength and bandwidth
In addition to the design wavelength, record the linewidth of the source, the wavelength drift with temperature and from unit to unit, and whether the lens is used at more than one wavelength.
In a conventional diffractive design, where the phase is wrapped at 2π and the meta-atom phase can be treated as nearly constant with wavelength, the focal length varies roughly in inverse proportion to wavelength. That relationship does not hold for dispersion-engineered designs, which control both the phase and its wavelength dependence [1].
For designs that hold the focus over a wide band, theory shows that for a given structure height and index contrast, the achievable bandwidth narrows as the aperture and NA increase [2]. A requirement that asks for wide bandwidth, large aperture and high NA together should be reviewed early.
Aperture and focal length
The aperture usually follows from the amount of light to be collected or from the beam diameter.
Focal length is the optical quantity used to design the phase profile. Record it as the distance from the patterned surface of the metalens to the focus, together with the medium in which the light is focused.
Working distance and its reference surface
Working distance is the mechanical gap between the element and the target. State the reference surface it is measured from: the patterned surface, the back of the substrate, or the surface of a protective layer or package window.
Record focal length and working distance as separate items. When the patterned surface faces the target and the light is focused in air, the two are nearly equal. When the light is focused through a substrate or a cover glass, they differ, so record its thickness and refractive index as well.
Field of view and incident angles
Decide whether the lens handles only an on-axis collimated beam or also light arriving at an angle. For imaging this is the field of view. For focusing and coupling it is the tilt and divergence of the input beam.
A simple hyperbolic phase profile produces large aberrations off axis. When a wide field of view is required, the options include a different phase function [3] or a design that uses two metasurfaces [4].
Polarization
Confirm the polarization state of the source (linear, circular or unpolarized) and whether the function must differ between polarizations. This requirement drives the choice of meta-atom geometry.
Rotationally symmetric structures, such as circular pillars on a symmetric lattice, keep polarization dependence low at normal incidence. At oblique incidence, however, the response to s- and p-polarized light can differ. Rotational symmetry alone does not guarantee a polarization-independent response at every angle of incidence.
For applications with a range of incident angles, check the unit-cell response for each polarization and angle. When meta-atom responses are passed to ray tracing, the wavelengths and incident angles computed in the RCWA simulation must also cover the range used in the optical system [5].
Illumination
Decide whether the incident light is close to a plane wave, a Gaussian beam or a diverging beam, and how much of the aperture it fills. Record the coherence as well, for example a laser or an LED. For the same lens, spot size and efficiency figures change when the illumination changes.
Packaging constraints
List the outline and thickness of the element, which side of the substrate carries the structures, whether there is a protective or adhesive layer, the margin required outside the clear aperture, and the operating temperature range.
If the structures are embedded in a resin or a similar material, the surrounding refractive index changes and so does the meta-atom response. Treat it as an optical requirement even though it originates in packaging.
Which parameters depend on one another
The items in a specification are not independent. Use the following relationships to decide which values to fix and which to accept as a consequence.
What you set
What moves with it
Relationship and assumptions
Aperture D and focal length f
NA
For a collimated beam at normal incidence focused to an on-axis point in air, NA = sin(arctan(D/2f)). The expression does not apply as written to finite object distances, off-axis points or focusing inside another medium
NA and wavelength λ
Diffraction-limited spot size, depth of focus
For a uniformly illuminated, aberration-free circular aperture, spot size scales with λ/NA and depth of focus with λ/NA² [6]. A smaller spot means a shallower depth of focus
NA, wavelength λ and unit-cell period p
Phase sampling
For a lens model that assigns a hyperbolic phase cell by cell, the Ansys metalens workflows give the sampling condition NA < λ/(2p) [7][8]. It is a design condition on phase sampling, not a fabrication rule for achievable dimensions
Aperture D and period p
Number of meta-atoms, layout data size
The number of structures scales with (D/p)². A tenfold increase in aperture means about a hundredfold increase in structures
Wavelength range and focal length f
Chromatic focal shift
In a conventional diffractive design, a longer focal length gives a larger focal shift for the same change in wavelength
Acceptance criteria
Do not leave a requirement as “high efficiency” or “high resolution”. Write it as a metric together with the conditions under which it is evaluated.
Choose the metrics from the application: delivered power and spot size for focusing, MTF across field and wavelength for imaging, agreement with the target intensity profile and efficiency for beam shaping, and coupling efficiency and misalignment tolerance for coupling.
Define the evaluation conditions with each metric. Focusing efficiency needs an integration region and a reference power (incident or transmitted). Spot size needs a definition, such as FWHM or the diameter containing a stated fraction of the power, and an evaluation plane. MTF needs the spatial frequency, field and wavelength weighting. Coupling efficiency needs the mode on the receiving side and the range of positional and angular misalignment.
Also separate the conditions that must be met from those that are desirable.
Transmission is not focusing efficiency
Transmission is the fraction of power that passes through the element, regardless of where it goes. Focusing efficiency is the fraction of power that arrives in a defined focal region. Transmission can be high while focusing efficiency is low, because power is lost to zero-order light, unwanted diffraction orders and scattering.
Even for published focusing efficiencies, inconsistent interpretation of experimental data has been pointed out [9]. In a specification, always write the number together with its definition. The definitions and practical evaluation methods are explained in How to Evaluate Metalens Performance.
Component performance and system performance
The metrics of the metalens alone (focusing efficiency, spot, wavefront) are different from the metrics of the system it is built into (image contrast, detected power, coupling efficiency). System performance also depends on the source, the other optical elements, the sensor and assembly errors.
In a specification, write the system-level requirement first and then derive the requirement allocated to the metalens.
Fabrication constraints
Confirm how the lens will be made at the same stage as the optical requirements. The range of dimensions that can be fabricated sets the range of usable meta-atoms, which in turn determines phase coverage and efficiency.
The items to confirm are the material and substrate, the fabrication process, the minimum feature size and gap, the structure height, the aspect ratio and the dimensional tolerances. The refractive index and absorption of the material set the required structure height and the transmission. The minimum feature size and gap set both ends of the dimension range available to the library. Height and aspect ratio limit the achievable phase range, and dimensional tolerances appear in performance as phase and transmission error.
Fabrication processes include electron-beam lithography, projection lithography and nanoimprint. Large all-glass metalenses made by deep-ultraviolet projection lithography have been reported [10], and there are foundry services that use nanoimprint [11]. A change of process changes some of the conditions available to the design, such as the minimum feature size or the maximum height. Confirm which ones for each process.
Feasible values must come from the intended fabrication provider. Values in the literature and general rules of thumb were obtained with other materials, equipment and conditions, and cannot be applied directly to your design.
Some foundries publish their conditions. Moxtek, for example, lists the minimum pillar dimension and gap, thickness, aspect ratio, and supported materials and substrates as design parameters for its metalens foundry service [11]. Ansys and Moxtek have also published a PDK whose meta-atom libraries take material properties, thickness and minimum feature size into account [12]. Both describe one provider’s specific processes. They are cited here as public examples only, and are not offered or arranged by LightBridge.
Estimate the effect of fabrication errors early as well. A study of silicon metasurfaces reports that metasurfaces for visible to near-infrared wavelengths require fabrication precision of the order of nanometers in dimensions and degrees in sidewall slope [13].
If the foundry has not been chosen, ask each candidate for the items above and keep them in the specification as open items. At LightBridge too, the fabrication method and its feasibility are confirmed case by case from the target wavelength, material and structure dimensions (see Design to Fabrication).
An illustrative specification
The table below shows how specifically a specification should be written. It is a hypothetical example prepared for illustration, not a design that LightBridge has simulated, manufactured or validated. Because the numbers differ for every application, the entries describe in words what to record.
Item
Example entry (illustrative)
Source of the value
Application and function
A focusing lens that brings single-wavelength near-infrared laser light onto a detector. A single metalens
System design
System layout
Light enters from the substrate side. The patterned surface faces the detector and the light is focused in air
System design
Source and illumination
A collimated Gaussian beam. The beam diameter is smaller than the clear aperture
Source datasheet
Wavelength and bandwidth
The center wavelength of the source, with its linewidth and the wavelength drift over the operating temperature range
Source datasheet
Aperture
A clear aperture equal to the beam diameter plus a margin. The outline follows the package dimensions
Beam diameter, housing design
Focal length
The distance from the patterned surface to the focus, as a value in air. This is the value used to design the phase profile
Optical design
Working distance
Stated with its reference surface. In this example, the gap from the outermost surface on the patterned side (the surface of the protective layer, if there is one) to the detector plane
Housing design
Incident angle
Normal incidence, with the allowed tilt at assembly
Assembly tolerance
Polarization
Linear, with a fixed orientation
Source datasheet
Acceptance criterion
The fraction of power reaching the active area of the detector, referenced to incident power. It must hold over the wavelength drift and tilt ranges
System requirement for detected power
Material and substrate
A high-index material with low absorption at the operating wavelength, on a glass substrate. Candidates are being confirmed with the foundry
Foundry
Fabrication process
Not decided. Prototyping and volume production may use different processes
Foundry
Minimum feature size and gap
Enter the values from the foundry’s design rules
Foundry
Height and aspect ratio
Enter the film thickness the foundry supports and the maximum aspect ratio
Foundry
Dimensional tolerances
Enter the range of variation in width and height. If not yet available, mark as needing guidance
Foundry
Specification checklist
Prepare the following information before a design or a consultation. Not everything has to be settled. What matters is separating the items you have confirmed from those you cannot yet decide.
Information to prepare
Why it matters
Status
Application and function (focusing, imaging, beam shaping, coupling)
Determines the type of phase profile and the evaluation metrics
Confirmed / Needs guidance
System layout (elements before and after, entrance side, surrounding media)
Determines the phase profile and the unit-cell simulation conditions
Confirmed / Needs guidance
Design wavelength and bandwidth
Determines the material, the wavelength conditions of the library and the range for chromatic evaluation
Confirmed / Needs guidance
Aperture
Determines the number of structures, the layout data size and the patterned area
Confirmed / Needs guidance
Focal length (with the medium)
Determines the phase profile and, with the aperture, NA
Confirmed / Needs guidance
Working distance and its reference surface
Determines the space available and how the substrate and protective layers are treated
Confirmed / Needs guidance
Field of view and range of incident angles
Determines the angular range of the library and the approach to aberration correction
Confirmed / Needs guidance
Polarization
Determines the meta-atom geometry
Confirmed / Needs guidance
Illumination
Determines the conditions for evaluating efficiency and spot size
Determines the substrate and the surrounding media
Confirmed / Needs guidance
Metrics and acceptance criteria
Determines when the design is complete and how much analysis is needed
Confirmed / Needs guidance
Material and substrate
Determines the structure height and the transmission
Confirmed / Needs guidance
Fabrication process and foundry
Determines which design rules apply
Confirmed / Needs guidance
Minimum feature size, minimum gap, height, aspect ratio
Determines the dimension range available to the library
Confirmed / Needs guidance
Dimensional tolerances
Determines the conditions for tolerance analysis
Confirmed / Needs guidance
Quantity and schedule
Determines which processes are realistic
Confirmed / Needs guidance
From specification to design and evaluation
The specification feeds three stages: calculating the electromagnetic response of the meta-atoms, designing and evaluating the lens from a library, and evaluating the optical system. The complete flow is laid out in the metalens and metasurface design workflow.
The phase and transmission of each meta-atom are calculated by electromagnetic simulation of the unit cell, using RCWA or FDTD in Ansys Lumerical. The results of a dimension sweep are collected into a meta-atom response library.
From the specification, the wavelength, material, substrate and surrounding media, polarization and range of incident angles become the simulation conditions. The minimum feature size, minimum gap and height set by the fabrication constraints define the dimension range to sweep and the entries to exclude from the library.
Library-based design and evaluation: Photonica Metalens Engine
Photonica Metalens Engine is the LightBridge design engine that designs the whole lens from a meta-atom response library. The electromagnetic response data for the meta-atoms comes from Ansys Lumerical RCWA and FDTD results.
Its design specification takes the aperture, focal length, design wavelength, phase-profile type, image plane and analysis conditions, fabrication-related constraints (a fixed height, the pitch, dimensional limits from the process) and the selected library. Most of the items organized in this article become design inputs as they are.
In the design step, the library entry whose phase is closest to the target is assigned at every placement point of the target phase profile. This is the phase-to-geometry mapping. The placement is then turned into a large-scale layout and written out as manufacturing data such as GDSII.
The optical performance of the assembled lens can be predicted from the same library responses: PSF, FWHM against the diffraction limit, Strehl ratio, focusing efficiency and MTF, among others. The metrics that correspond to your acceptance criteria can be checked before manufacturing data is produced.
These results are predictions calculated by applying the library response at each placement point. They rest on the conditions under which the library was built (material, wavelength, incident angles, and simulation as a periodic unit cell), and they do not include effects outside the library, such as interaction between neighboring structures that differ strongly. The definition of each metric is recorded in the output data, so read the results against the definitions in your specification.
The optical system that contains the metalens is evaluated and optimized in Ansys Zemax OpticStudio. PSF, MTF and aberrations are evaluated across field and wavelength with the source, the other optical elements and the sensor in place, and compared with the system-level acceptance criteria. Design data from Photonica Metalens Engine can be passed to this evaluation.
When the metalens is modeled as an ideal phase surface, diffraction efficiency cannot be calculated from the phase profile [14]. Use the method suited to each metric: library-based evaluation or electromagnetic simulation for the efficiency of the element, and optical-system evaluation for imaging performance.
If the results do not meet the acceptance criteria, return to the specification and review which items were fixed and which were accepted as consequences.
Request a Photonica Metalens Engine evaluation
Once you have organized the intended application, the specifications you already know and the questions still open, request an evaluation of Photonica Metalens Engine. You can apply even if your specification is incomplete.
The form opened by the link below has Photonica Metalens Engine selected as the product of interest.
E. Arbabi, A. Arbabi, S. M. Kamali, Y. Horie and A. Faraon, “Controlling the sign of chromatic dispersion in diffractive optics with dielectric metasurfaces,” Optica 4, 625-632 (2017). https://doi.org/10.1364/OPTICA.4.000625
A. Arbabi, E. Arbabi, S. M. Kamali, Y. Horie, S. Han and A. Faraon, “Miniature optical planar camera based on a wide-angle metasurface doublet corrected for monochromatic aberrations,” Nature Communications 7, 13682 (2016). https://doi.org/10.1038/ncomms13682
R. Menon and B. Sensale-Rodriguez, “Inconsistencies of metalens performance and comparison with conventional diffractive optics,” Nature Photonics 17, 923 (2023). https://doi.org/10.1038/s41566-023-01306-w
J.-S. Park et al., “All-Glass, Large Metalens at Visible Wavelength Using Deep-Ultraviolet Projection Lithography,” Nano Letters 19, 8673-8682 (2019). https://doi.org/10.1021/acs.nanolett.9b03333
We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.
Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.
Essential Website Cookies
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to deliver the website, refusing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.
We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.
We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.
Google Analytics Cookies
These cookies collect information that is used either in aggregate form to help us understand how our website is being used or how effective our marketing campaigns are, or to help us customize our website and application for you in order to enhance your experience.
If you do not want that we track your visit to our site you can disable tracking in your browser here:
Other external services
We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.
Google Webfont Settings:
Google Map Settings:
Google reCaptcha Settings:
Vimeo and Youtube video embeds:
Other cookies
The following cookies are also needed - You can choose if you want to allow them:
Privacy Policy
You can read about our cookies and privacy settings in detail on our Privacy Policy Page.