How to Evaluate Metalens Performance: Focusing Efficiency, Spot Size, MTF, and Aberrations
How to evaluate a designed metalens at four levels, from meta-atom to optical system: focusing-efficiency definitions, transmission versus efficiency, FWHM and the diffraction limit, PSF and MTF assumptions, aberrations, and tolerance.
Published
No single number tells you whether a metalens performs well. A design can hit its target phase and still focus poorly. It can produce a tight central spot while pushing a large share of the power into side lobes. It can be close to diffraction-limited on axis and unusable at the edge of the field. Each metric answers a different question, and each one is only meaningful together with its definition and test conditions.
This article assumes the basics covered in What Is a Metalens? and focuses on one engineering question: how do you determine whether a designed metalens actually performs well? The design process itself is laid out on the metalens design workflow page.
Four levels of evaluation
Metalens performance is best evaluated at four levels:
Meta-atom (unit cell) → realized metalens (layout) → focal field → imaging / optical system
At the meta-atom level, the question is whether each structure delivers the required phase with enough transmission. At the realized-lens level, it is how well a finite set of structures reproduces the target phase profile across the aperture. At the focal-field level, it is where the light goes, how much of it arrives, and in what shape. At the system level, it is whether the point image and contrast meet the application’s requirements across field and wavelength.
A good result at one level does not guarantee a good result at the next. When a system-level metric disappoints, the cause is traced back down the hierarchy.
The four levels of metalens performance evaluation and the main metrics at each level. Fabrication tolerance, wavelength, field angle and polarization are checked at every level by varying the conditions.
Metalens performance metrics at a glance
Metric
What it tells you
Level
Typical method / tool
Common mistake
Phase error
Whether the required wavefront is generated
Meta-atom, layout
RCWA/FDTD sweeps; realized minus target phase, modulo 2π
Subtracting phases without handling the 2π wrap
Transmission
How much power passes through the element
Meta-atom, layout
RCWA/FDTD
Treating high transmission as high focusing efficiency
Focusing efficiency
How much power reaches a defined focal region
Focal field
Propagation to the focal plane and power integration
Quoting a percentage without its integration region and reference power
Focal position
Whether the actual focus is where it was designed to be
Focal field
Axial intensity scan
Evaluating only in the nominal focal plane
FWHM / spot size
How sharp the central peak is
Focal field
Focal-plane intensity profiles
Assuming smaller is always better and ignoring side lobes
PSF
The image of a point source
Focal field, system
Wave propagation; OpticStudio FFT/Huygens PSF
Equating any focal spot with the imaging PSF
MTF
Contrast transfer versus spatial frequency
System
Fourier transform of the intensity PSF (incoherent imaging); OpticStudio
Applying the incoherent relation to coherent illumination
Aberrations
Departure of the wavefront from the ideal reference sphere
System
Wavefront analysis; ray tracing
Checking only on axis at the design wavelength
Wavelength dependence
Whether performance holds away from λdesign
All levels
Wavelength sweep
Judging a band from a single wavelength
Field dependence
Whether off-axis images remain usable
System
PSF/MTF/aberrations versus field; oblique-incidence meta-atom analysis
Extrapolating on-axis results to a wide field
Polarization dependence
Whether performance holds for the intended polarization state
Meta-atom, system
Per-polarization analysis
Not recording which polarization was tested
Fabrication sensitivity
How much performance moves with fabrication error
All levels
Sweeps of width, height, sidewall angle; Monte Carlo
Selecting a design on nominal performance alone
Focusing efficiency: the definition is part of the number
Focusing efficiency is the most quoted metalens figure of merit, and it is not defined the same way in every paper. The general form is:
ηfocus = Pfocus / Pref
where Pfocus is the power crossing a specified region of the focal plane and Pref is a reference power. Both terms have to be defined before the number means anything.
The numerator. Common choices for the integration region are a disk out to the first Airy minimum, a disk whose radius is a multiple of the measured FWHM (three times is common), or an angular cone in the far field matching the design NA [1][2]. In experiments, the radius of the iris placed in the focal plane has ranged from 3× to 18× the FWHM or more, and Menon and Sensale-Rodriguez argue that an efficiency reported without the integration radius is incomplete [3].
The choice matters even for a perfect lens. For an unaberrated, uniformly illuminated circular aperture (scalar Airy pattern), about 84% of the power lies inside the first dark ring and about 94% inside a radius of three FWHM [4]. The integration radius alone shifts the result by roughly ten percentage points. At high NA the picture changes again: even an aberration-free flat lens does not produce an Airy pattern, so a fixed multiple of the FWHM encloses a different fraction of the power [5].
The denominator. Pref may be the total incident power, the power incident on the physical aperture, or the transmitted power. Normalizing to incident power gives an absolute efficiency that includes reflection and absorption; normalizing to transmitted power gives a relative efficiency, the fraction of transmitted light that reaches the focus [6].
The test conditions. Wavelength, polarization, illumination profile (plane wave or Gaussian beam, and how fully it fills the aperture), NA, aperture size, angle of incidence, and the plane in which the measurement is made all change the value. When a polarization-dependent design is compared with a polarization-independent one, the comparison should be made for unpolarized input [3].
The practical lesson: two published focusing-efficiency percentages cannot be compared unless their numerators, denominators, and test conditions are compatible. Record the definition with every number, and keep the encircled-power curve P(r)/Pref rather than a single value so it can be converted to another definition later.
In simulation, the field is propagated from the lens (a full FDTD run for a small lens, or a near field stitched from meta-atom responses) to the focal plane, and power is integrated there. Integrate the normal component of the Poynting vector, not |E|²: at high NA the longitudinal field component is significant, and |E|² no longer tracks the power flow through the plane. In the lab, the power through an iris in the focal plane is compared with the power measured with the lens removed [1].
Fraction of transmitted power inside a far-field cone, plotted against the cone half-angle; the dashed line marks the design-NA cone. The value depends on which angular range is counted as reaching the focus, and because the denominator is transmitted power it is not directly comparable with an efficiency normalized to incident power. Scalar far-field result computed by the built-in analysis of Photonica Metalens Engine from the response of the placed library entries, for a design using a TiO₂ pillar library (532 nm, 250 nm pitch); not an electromagnetic simulation of the whole lens.
Transmission is not focusing efficiency
Three quantities are often used interchangeably and should not be:
Transmission efficiency: the fraction of incident power transmitted through the element, regardless of direction or diffraction order.
Diffraction efficiency: generally, the fraction of incident power coupled into a specified diffraction order or optical channel.
Focusing efficiency: as commonly reported for metalenses, usually defined by the power entering a specified region around the focus.
The two efficiencies are not defined identically across the literature, so distinguish them according to their stated definitions.
With all three normalized to incident power, focusing efficiency cannot exceed transmission, because the focused power is part of the transmitted power. The difference is light that is transmitted but does not arrive in the focal region: side lobes of the focal spot, the undiffracted zero order and other unwanted orders, background from phase errors and quantization, and scattering from fabrication roughness. High transmission is necessary for high focusing efficiency, but it is not sufficient.
At the meta-atom level, Ansys Lumerical RCWA computes transmission and reflection per diffraction order for periodic unit cells, and geometry sweeps build the phase and transmission library [7]. Polarization- and angle-dependent responses are characterized at this level too. FDTD handles finite structures, coupling between dissimilar neighbors, and full simulations of small lenses; propagating its near field to the focal plane gives focusing efficiency and side lobes directly from an electromagnetic solution.
Meta-atom library QA report for TiO₂ pillars (532 nm, 250 nm pitch): phase delay and transmission over pillar radius (40 to 110 nm) and height (400 to 1,200 nm) computed with RCWA, phase coverage versus height, and the phase and transmission coverage at the selected height. The note at the top gives the maximum |t|² difference found in an FDTD cross-check. Library QA output from Photonica Metalens Engine, based on Ansys Lumerical RCWA results.
How to build the phase and transmission library, and how to judge its quality, is covered in Metalens Unit Cell Design.
Distinguish the nominal focal length f from the position where intensity actually peaks. Find the actual focus with an axial scan of the on-axis intensity I(z), and look at the x–z intensity map for secondary foci. Sample z more finely than the axial extent of the focus, which scales roughly as λ/NA² at low NA. When aberrations are present, the plane of peak intensity and the plane of minimum RMS spot size can differ, so state which criterion was used.
A focal shift Δf = zpeak − fdesign can come from errors in the realized phase, from how the substrate or surrounding medium is treated, or from diffraction itself: at low Fresnel number a²/(λf), where a is the aperture radius, the intensity maximum of even an aberration-free converging wave moves toward the lens [8]. Measurements of a low-NA metalens have found the brightest point closer to the lens than the design focal length [9].
For wavelength-dependent evaluation, determine f(λ) at each wavelength. A simple wrapped hyperbolic profile follows f(λ) ≈ f₀λ₀/λ to first order, set by the zone geometry. Meta-atom dispersion mainly changes how power is split between orders and adds phase error, so the focal distribution and efficiency at each wavelength should come from wavelength-resolved responses.
Spot size and FWHM
The FWHM is the width between the points where focal-plane intensity falls to half its maximum. Measure it in the actual focal plane, along both x and y; report both if the spot is not circular.
A smaller FWHM is not automatically better. Some designs narrow the central peak at the cost of stronger side lobes or lower efficiency, and sub-diffraction FWHM values have been traced to power moved into side lobes rather than to better focusing [2]. FWHM is a reliable indicator of diffraction-limited operation only when the spot actually resembles an Airy pattern [6]. Read FWHM together with side-lobe level, the power outside the central lobe, and focusing efficiency.
Comparing with the diffraction limit
For a uniformly illuminated, aberration-free circular aperture, the first Airy minimum lies at a radius r ≈ 0.61 λ/NA, and the intensity FWHM (a diameter) is about 0.51 λ/NA [4]. Radius and diameter, and first minimum and FWHM, are different quantities; mixing them up produces misleading comparisons.
These expressions come from scalar diffraction theory at low to moderate NA (NA = n sin θ) and assume uniform illumination; a Gaussian beam changes the reference spot. As NA grows, vector effects become significant: the electric energy density |E|² of a linearly polarized focus elongates along the polarization direction, while Sz stays more symmetric [10][11], so state which quantity the FWHM was taken from. For a high-NA metalens, compare against the focal distribution of an ideal lens with the same NA, wavelength, illumination, and polarization, computed with the same electromagnetic model, rather than against the scalar formula.
PSF: defined by the configuration
The point spread function is the intensity distribution an optical system forms in the image plane from a point source. It is not simply another name for the focal spot. The PSF is defined only once the object distance, field position, wavelength, pupil illumination, polarization, and image plane are fixed.
For a lens imaging an object at infinity, an object point corresponds to a plane wave, so the focal-plane intensity produced by a plane wave that uniformly fills the aperture corresponds to the PSF at that field angle and wavelength. A Gaussian laser beam that partly fills the aperture, or a measurement in a plane other than the image plane, does not give the imaging PSF. A hyperbolic metalens designed for infinity and used at a finite conjugate also adds spherical aberration. The focal spot and the imaging PSF are closely related but not interchangeable, so state which one was measured or simulated.
In the PSF, examine the width and shape of the central lobe, the level and position of side lobes, and any asymmetry: a comatic tail off axis, or polarization-induced elongation at high NA. General PSF metrics such as encircled energy are covered in Image Quality Analysis.
MTF: what it reveals about a metalens
For the general definition and the calculation methods, see MTF (Modulation Transfer Function). The points below are specific to metalenses.
Start with the imaging assumption. In incoherent imaging (self-luminous objects, diffuse illumination), image intensity is the convolution of object intensity with the intensity PSF. The optical transfer function is the Fourier transform of the intensity PSF normalized at zero frequency, and the MTF is its magnitude. In coherent imaging (for example, laser illumination), the system is linear in complex amplitude, and its transfer behavior is described by the coherent transfer function, set by the pupil function. Because coherent imaging is not linear in intensity, an MTF computed from the intensity PSF does not in general predict image contrast [12]. Partially coherent illumination needs a further treatment.
MTF matters for metalenses because it exposes degradation a focal spot hides. The OTF is normalized by the total power in the PSF, so light that reaches the image plane as a broad halo (zero-order leakage, unwanted orders, scattered light) produces a sharp drop at low spatial frequencies and lowers contrast across the band. When the central lobe is close to the diffraction limit but the MTF disappoints, look for this halo first. Side lobes, aberrations, and degradation with field and wavelength also show up as lost contrast at the frequencies the application needs, such as the sensor’s Nyquist frequency.
Light that never reaches the sensor (reflection, absorption) does not appear in the MTF at all, so MTF is no substitute for efficiency; metrics combining MTF with signal-to-noise ratio have been proposed for exactly this reason [13]. Numerically, wide-angle scatter falling outside the computed PSF window is missed as well, and a window that is too small overstates the MTF.
Aberrations
Aberrations are evaluated as the wavefront’s departure from the ideal reference sphere. Subtracting the ideal lens phase from a simulated or measured phase map gives the metalens wave aberration directly [9]; decomposition into Zernike terms is covered in Wavefront Analysis.
Which aberrations matter depends on the phase function, the operating conditions, and the system. A hyperbolic profile is ideally aberration-free on axis, at the design wavelength, for an object at infinity. Off axis it develops coma, astigmatism, and field curvature; distortion changes image geometry rather than sharpness and is evaluated separately. A different object distance, or an unaccounted substrate or cover glass, introduces spherical aberration. Departing from the design wavelength produces longitudinal and lateral chromatic aberration. Not every metalens shows all of these: a remote aperture stop combined with a modified phase profile, or a second metasurface, can correct off-axis aberrations [14]. Evaluate aberrations as functions of wavelength, field angle, and aperture or NA.
Strehl ratio
The Strehl ratio is the peak intensity of the actual PSF divided by the peak intensity of an aberration-free system with the same aperture, wavelength, and illumination. Normalization needs care with metalenses: normalizing both PSFs to the same transmitted power isolates aberrations, while referencing a 100%-efficient ideal lens folds efficiency losses into the number. State which was used. A Strehl ratio of 0.8 corresponds to an RMS wavefront error of about λ/14 (the Maréchal criterion) and is a conventional guideline for calling a weakly aberrated system diffraction-limited [4]. It is not a universal acceptance threshold for metalenses.
Beyond nominal conditions: wavelength, field, and polarization
Wavelength
Sources have bandwidth and drift, and imaging sensors respond over a band, so evaluation at λdesign alone is not enough. A wrapped phase profile is exact only at the design wavelength, and meta-atom phase and transmission are dispersive. Evaluate focal position f(λ), focusing efficiency η(λ), FWHM(λ), PSF(λ), and MTF(λ). Distinguish two questions: performance at each wavelength’s own best focus describes the lens; performance in a fixed sensor plane describes the system. Decide whether the efficiency integration radius stays fixed or scales with wavelength. For broadband sources, evaluate polychromatic PSF and MTF weighted by the source spectrum and sensor response.
Field angle and incidence angle
For imaging, always evaluate off axis. At oblique incidence, aberrations appear and the meta-atom phase and transmission themselves change from their normal-incidence values. Evaluate spot and PSF versus field, tangential and sagittal MTF versus field, aberrations versus field, and efficiency versus incidence angle. A single-layer metalens that is near diffraction-limited on axis can degrade quickly with field angle [6]; conversely, some wide-field designs deliberately give up on-axis diffraction-limited resolution to achieve uniform performance over a large field [15]. On-axis results do not transfer to wide-field use.
Polarization
Test conditions follow the architecture. Propagation-phase designs with rotationally symmetric pillars are largely polarization-insensitive at normal incidence, but check this at oblique incidence and in high-NA outer zones. Geometric-phase designs are evaluated per circular handedness, and polarization-multiplexed designs per channel, including crosstalk. Choose among linear orientation, s and p (TE and TM) at oblique incidence, left- and right-circular, and unpolarized input to match the application; for unpolarized use, average two orthogonal states. Not every metalens is polarization-sensitive, but always record the state tested.
Worked example: scaling the reference design
The reference design published on LightBridge’s Photonica Metalens Engine product page (TiO₂ pillars, 532 nm, 1 mm aperture, f = 5 mm, 250 nm pitch) gives a sense of the scales involved. Every value below follows from the design parameters; none is a performance result.
Quantity
Value
How it is obtained
NA
≈ 0.0995
sin(arctan(0.5 mm / 5 mm))
First Airy minimum (radius)
≈ 3.3 μm
0.61 λ/NA
Airy FWHM
≈ 2.7 μm
0.51 λ/NA
Depth of focus (conventional)
≈ ±27 μm
±λ/(2NA²)
Number of 2π zones
≈ 47
(√(a² + f²) − f)/λ
Pillars per 2π zone at the edge
≈ 21
λ/(p·NA)
Fresnel number
≈ 94
a²/(λf)
Focal shift for +10 nm (first order)
≈ −94 μm
−fΔλ/λ
At NA ≈ 0.1 the scalar Airy pattern is a reasonable diffraction-limited reference. An integration radius at the first minimum (≈ 3.3 μm) or at three FWHM (≈ 8.2 μm) puts about 84% or 94% of an ideal lens’s power in the numerator. With about 21 pillars per 2π even at the edge and a large Fresnel number, a focal shift at the design wavelength points first to realized-phase errors or substrate handling. A 10 nm wavelength change, by contrast, moves the focus by about 94 μm, far beyond the ±27 μm depth of focus. Actual efficiency, FWHM, PSF, MTF, and tolerances must come from electromagnetic and system-level simulation.
Fabrication tolerance
Evaluate sensitivity to pillar diameter or width (CD error, etch bias), height (etch depth, film thickness), sidewall angle, corner rounding, material index, layer thickness, and, where relevant, placement error such as write-field stitching. Start at the unit cell: the geometry sweeps give phase and transmission sensitivities, which are highest for resonant structures and where phase changes steeply with geometry. Then separate systematic errors (all structures biased the same way) from random ones, convert each into a lens-level phase error, and evaluate the effect on focusing efficiency, focus, PSF, and MTF. Systematic errors that depend on the local target phase can lower efficiency and create secondary foci while leaving focal length and FWHM nearly unchanged [16]; uncorrelated random errors mostly add scattered background, while slowly varying errors such as film-thickness nonuniformity act as wavefront aberrations.
A design with slightly lower nominal performance can be the better choice if it is much more tolerant of fabrication error. Acceptable ranges depend on the application and the process; there is no universal threshold. System-level tolerancing, including assembly errors, is covered in Tolerance Analysis.
Ideal phase versus realized metalens
One of the most important distinctions in metalens evaluation is whether a reported result describes the ideal phase profile or the device that will actually be made. The gap opens in five stages:
Stage
Question
Typical evaluation
1. Ideal analytical phase
Does the phase function give the intended optical behavior?
Focus, PSF, and MTF from propagating the ideal phase; the baseline for later stages
2. Finite meta-atom library
What error is introduced by mapping a continuous phase onto available geometries?
Target-versus-realized phase error (map and RMS), mean and spread of transmission, phase coverage
3. Electromagnetic response
What are the actual phase, transmission, polarization response, and neighbor coupling?
Validity of the local periodic approximation; FDTD of lens sections or small full lenses
4. Physical layout and fabrication
How do placement, discretization, and fabrication deviations change the device?
Placement grid, polygon approximation, performance with CD bias and sidewall angle
5. Optical system
After integration, do PSF, MTF, and aberrations meet requirements across field and wavelength?
PSF, MTF, aberrations versus field and wavelength
Stage 1 tells you whether the phase function is right; stages 4 and 5 tell you whether the device you will fabricate meets the requirement. Evaluating the same metric at each stage shows where performance is lost. The local periodic approximation loses accuracy where neighboring structures differ sharply [17][18], so a clean stage 2 result still needs stage 3 confirmation.
Stages 2 to 4, turning a target phase into a physical arrangement of structures, become a large computation in their own right as the aperture grows. Photonica Metalens Engine handles this implementation step: target-phase handling, response-library lookup, geometry assignment, large-scale placement, and layout and GDS generation, using response libraries built from Ansys Lumerical RCWA and FDTD results. According to the product page, it reports achieved phase, transmission, and the distribution and RMS of phase error for a placement: a stage 2, placement-level check that the page states is not an electromagnetic analysis of the whole lens. Results from the built-in analyses listed there should likewise be read against the definitions and assumptions discussed here. The realized layout is then evaluated with appropriate tools, such as FDTD on lens sections or OpticStudio at the system level.
At the system level the metalens is represented not as individual nanostructures but as a surface, typically defined by a phase profile, inside the optical model. Zemax OpticStudio then evaluates PSF, MTF, aberrations, and spot diagrams across field and wavelength. How physically faithful those results are depends on the representation.
An ideal phase surface bends rays correctly into the design diffraction order, so it gives the aberrations, PSF, and MTF of the phase function at system level. It carries no information about how much power each order contains, so diffraction efficiency cannot be computed from it [19], and its wavelength behavior is that of an ideal diffractive surface rather than of the meta-atoms. Microstructure-dependent diffraction efficiency, power in unwanted orders, and microstructure scattering are not inherently part of a phase-only model. An MTF from such a model describes the phase function, not the fabricated device.
Electromagnetic results can be brought into the system model. Diffraction-order efficiencies and polarization responses computed with Lumerical can be passed to the ray trace as data tabulated over wavelength and incidence angle (the Lumerical Sub-Wavelength Model), and a large metalens can be defined from a meta-atom response database and the target phase for ray tracing [18][20]. These routes add efficiency and polarization information, but they rely on the local periodic approximation and have limits where the phase changes abruptly and at the outermost cells of the lens [18]. Worked procedures are in Metalens Design Across Lumerical and Zemax and Large-Scale Metalens: Ray Propagation. Whatever route is used, report the metalens representation with every system-level result.
In practice, start from the question. Whether a unit cell generates the intended phase is answered by phase error and transmission, and how well the library reproduces the target phase by placement-level phase error. How much power reaches the focus is answered by focusing efficiency with its definition stated; where the focus is and how concentrated it is, by axial intensity, FWHM and side lobes. Whether the lens can form a useful image is judged from PSF and MTF, and robustness to field angle, wavelength, polarization and fabrication error by sweeping each condition and tracking the same metrics. For an imaging metalens, a minimum checklist looks like this:
Meta-atom phase and transmission
Target-versus-realized phase error
Focal position
Focusing efficiency, with its definition
Focal-plane intensity and FWHM
Side-lobe behavior
PSF
MTF
Wavelength sweep
Field-angle sweep
Polarization response, where relevant
Fabrication tolerance
The required metrics and acceptance criteria depend on the application. A beam-shaping metalens is judged on its match to the target intensity profile and its efficiency; an imaging metalens on MTF across field and wavelength; a sensor optic on encircled power within the detector area; a polarization element on extinction ratio or conversion efficiency. One set of criteria does not fit them all.
How to set metrics and acceptance criteria as part of a specification, before the design starts, is covered in Before Starting a Metalens Design.
Evaluation environment at LightBridge
LightBridge provides an environment that combines electromagnetic analysis in Ansys Lumerical, placement and layout generation in Photonica Metalens Engine, and system-level evaluation in Ansys Zemax OpticStudio. Our design and simulation services cover the work from choosing the analysis method to evaluating the results, and Design to Fabrication connects layouts to prototyping.
No single metric is enough. Evaluate meta-atom phase and transmission, realized phase error, focusing efficiency, focal position and FWHM, and system-level PSF, MTF, and aberrations, across wavelength, field, polarization, and fabrication error.
How is metalens focusing efficiency defined?
As power in a defined focal-plane region divided by a reference power. State the integration region (first Airy minimum, three FWHM, or a design-NA cone), the reference (incident or transmitted power), and the wavelength, polarization, illumination, and NA.
Why can’t published focusing efficiencies be compared directly?
Papers use different integration radii, reference powers, and test conditions. Even for an ideal Airy pattern, choosing the first minimum or three FWHM as the integration radius changes the result by about ten percentage points.
What is the difference between transmission and focusing efficiency?
Transmission counts all transmitted power wherever it goes; focusing efficiency counts only the power reaching the focal region. Side lobes, the zero order, unwanted orders, and scattered light are transmitted but not focused.
Is a smaller focal spot always better?
No. A narrow FWHM can coexist with strong side lobes, low efficiency, or a poor MTF. Compare with an ideal lens under the same conditions and check side lobes and efficiency.
What do PSF and MTF tell you about a metalens?
The PSF is the image of a point source in a specific configuration. For incoherent imaging, the MTF shows how much contrast survives at each spatial frequency, including losses caused by halos and side lobes.
Can a metalens reach the diffraction limit?
Near-diffraction-limited focusing has been reported. Whether a claim holds depends on the reference (scalar or vector, illumination, polarization) and on whether side lobes and efficiency were evaluated too.
Should I use FDTD or RCWA for metalens evaluation?
RCWA suits periodic unit cells: phase, transmission, and diffraction orders across geometry sweeps. FDTD handles finite structures, neighbor coupling, and full simulations of small lenses, including the focal field.
What can Zemax OpticStudio evaluate for a metalens?
System-level PSF, MTF, aberrations, and spot diagrams across field and wavelength. Fidelity depends on the metalens representation; an ideal phase surface omits microstructure-dependent diffraction efficiency and scattering.
How do fabrication errors affect metalens performance?
Errors in width, height, sidewall angle, and refractive index change meta-atom phase and transmission, appearing as lower efficiency, background, secondary foci, or aberrations. Sweep them and track the metric that matters.
References
A. Arbabi, Y. Horie, A. J. Ball, M. Bagheri and A. Faraon, “Subwavelength-thick lenses with high numerical apertures and large efficiency based on high-contrast transmitarrays,” Nature Communications 6, 7069 (2015). https://doi.org/10.1038/ncomms8069
E. Bayati, A. Zhan, S. Colburn and A. Majumdar, “Role of refractive index in metalens performance,” Applied Optics 58, 1460 (2019). https://doi.org/10.1364/AO.58.001460
R. Menon and B. Sensale-Rodriguez, “Inconsistencies of metalens performance and comparison with conventional diffractive optics,” Nature Photonics 17, 923 (2023). https://doi.org/10.1038/s41566-023-01306-w
M. Born and E. Wolf, Principles of Optics, 7th (expanded) ed., Cambridge University Press (1999).
A. Arbabi and A. Faraon, “On ‘Inconsistencies of metalens performance and comparison with conventional diffractive optics’,” arXiv:2410.12559 (2024). https://arxiv.org/abs/2410.12559
P. Lalanne and P. Chavel, “Metalenses at visible wavelengths: past, present, perspectives,” Laser & Photonics Reviews 11, 1600295 (2017). https://doi.org/10.1002/lpor.201600295
B. Richards and E. Wolf, “Electromagnetic diffraction in optical systems II. Structure of the image field in an aplanatic system,” Proceedings of the Royal Society A 253, 358 (1959). https://doi.org/10.1098/rspa.1959.0200
R. Dorn, S. Quabis and G. Leuchs, “The focus of light – linear polarization breaks the rotational symmetry of the focal spot,” Journal of Modern Optics 50, 1917 (2003). https://doi.org/10.1080/09500340308235246
J. W. Goodman, Introduction to Fourier Optics, 4th ed., W. H. Freeman (2017).
J. Engelberg et al., “How good is your metalens? Experimental verification of metalens performance criterion,” Optics Letters 45, 3869 (2020). https://doi.org/10.1364/OL.394680
A. Arbabi, E. Arbabi, S. M. Kamali, Y. Horie, S. Han and A. Faraon, “Miniature optical planar camera based on a wide-angle metasurface doublet corrected for monochromatic aberrations,” Nature Communications 7, 13682 (2016). https://doi.org/10.1038/ncomms13682
Y. Zhu et al., “The Impact of Manufacturing Imperfections on the Performance of Metalenses and a Manufacturing-Tolerant Design Method,” Micromachines 13, 1531 (2022). https://doi.org/10.3390/mi13091531
We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.
Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.
Essential Website Cookies
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to deliver the website, refusing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.
We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.
We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.
Google Analytics Cookies
These cookies collect information that is used either in aggregate form to help us understand how our website is being used or how effective our marketing campaigns are, or to help us customize our website and application for you in order to enhance your experience.
If you do not want that we track your visit to our site you can disable tracking in your browser here:
Other external services
We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.
Google Webfont Settings:
Google Map Settings:
Google reCaptcha Settings:
Vimeo and Youtube video embeds:
Other cookies
The following cookies are also needed - You can choose if you want to allow them:
Privacy Policy
You can read about our cookies and privacy settings in detail on our Privacy Policy Page.